Class C/D Volumetric Water Meter

Model NO.
AR. VM. 0D
Application
Civil, Industrial
Principle
Volumetric Meter
Medium Pressure
High-pressure Water Meter
Work Environment
Dry Water Meter
Stucture
Traditional
Transport Package
Carton Box/Wooden Pallet
Trademark
YT
Origin
China
HS Code
902820
Production Capacity
30000PCS/Month
Reference Price
Please contact us for quote

Product Description

Class C/D Volumetric Water Meter

Volumetric Rotary Piston Water Meter

 
> APPLICATION
  1. Recording the total amount of cold water flowing through the water pipe.
  2. The pure water meter is used to record the total amount of cold water flowing through a direct drinking water pipeline.
 
> FEATURES
  1. This series of water meter adopts a rotary piston type metering mechanism with the advantage of high measuring precision. The counting mechanism adopts a special liquid package, which has the advantages of clear reading, light appearance and check valve on the water intake to prevent back-flow, etc. According to customers' requirements, it can be converted into electrical signal output and thus achieve the purpose of remote reading.
  2. Pure water meter is a kind of volumetric rotary water meters with the application of the actual measured principle to record the total amount of drinking water through the piston rotation. The counter is separated from the water, so the numerical value showed is clear. The materials used are in accordance with the hygienic standard of drinking water meter. This water meter has the merits of small starting flow, high measuring accuracy, health, easy reading and so on, which is especially suitable for occasions with good water quality and high water fee.

Class C/D Volumetric Water Meter Class C/D Volumetric Water Meter Class C/D Volumetric Water Meter
Class C/D Volumetric Water Meter   Class C/D Volumetric Water Meter

> MAIN TECHNICAL PARAMETERS
    Temperature level: T30
    Pressure level: MAP10
    Pressure loss level:   P63
    Upstream flow sensitivity level: U0
    Downstream flow sensitivity level: D0

 
> MAXIMUM PERMISSIBLE ERROR
   A) Low area (Q1 ≤ Q < Q2) maximum permissible error is ± 5%.
   B) High area ( Q2 ≤ Q < Q4) maximum permissible error is ± 2%.

 
Class C/D Volumetric Water Meter


 
 

 